Expand description
Binning for calibration curves and error metrics.
The gate protocol pins 15 equal-mass bins (crate::protocol::GATE_BIN_COUNT) for
ECE and reliability curves. Equal-mass (equal-count) binning is used rather than the
classic equal-width ECE binning because real decision distributions are peaked: under
equal-width binning nearly all mass lands in one or two top bins and the curve says
nothing about the rest of the confidence range. Equal-width binning is retained for
the class-wise SCE, whose published definition is static (Nixon et al. 2019); ACE is